Product Test Results

Test Methods

Use sterilised by passing through 75% alcohol of the purifier.

500 ml of sterile water was allowed to pass through the purifier

10 ml of test micro-organism inoculum consisting of 108 cells was added into 1 litre sterile diluent (0.1% peptone) and pumped 500 ml through the system for testing.

The bacterial counts before and after passing through the system were determined in accordance with: FDA bacteriological Analytical Manual Online, January 2001 Chapter 3 “Aerobic Plate Count”

Test Organisms

Escherichia coli ATCC 8739

Legionella pneumophila ATCC 33152

 

Test Results

Test microorganism

Total Bacteria Count

CFU/ml
(Before the system)

Total Bacteria Count
CFU/ml

(After the system)

Reduction %

Escherichia coli
ATCC 8739

8.0 x 104

< 1

>99.99

Legionella pneumophila

ATCC 33152

2.0 x 104

< 1

>99.99

 

Test Results

Test microorganism

Total Bacteria Count

CFU/ml
(Before the system)

Total Bacteria Count
CFU/ml

(After the system)

Reduction %

Escherichia coli
ATCC 8739

8.0 x 104

< 1

>99.99

Legionella pneumophila

ATCC 33152

2.0 x 104

< 1

>99.99